Undervoltage
Honeywell
AC output voltage below acceptable range
Generator runs but output voltage is low; controller may show 'Undervoltage' or transfer switch refuses to transfer load.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak engine (underspeed under load), Failing voltage regulator, Loose alternator output connections, Shorted stator winding
How to Fix / Troubleshooting
Safety first: Isolate the generator from the home by opening the main generator breaker. Turn OFF the unit and disconnect battery negative before internal inspection.
Steps:
- Check engine performance: Listen for bogging or misfiring under load. If the engine cannot maintain RPM, address fuel/ignition issues first.
- Inspect alternator connections: Tighten all lugs at the alternator output terminals and at the internal breaker. Look for heat discoloration or melted insulation.
- Inspect AVR: Check the AVR for burnt components or odor. Reseat connectors.
- Voltage test: With a meter and proper PPE, run the generator unloaded and measure voltage. If low even with a healthy engine, replace the AVR with the correct Honeywell part.
- Further diagnosis: If voltage remains low after AVR replacement, the alternator stator or rotor may be damaged and should be tested by a generator technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Voltage Regulator (AVR)
Check Price on Amazon