E15
Hyundai Power Frequency Out of Range

Generator runs but E15 is displayed and the unit may not transfer load.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect governor setting, Engine speed sensor fault, Heavy cyclic load, Controller frequency setpoint misconfigured

How to Fix / Troubleshooting

Safety first: Disconnect non-essential loads and place the generator in MANUAL for testing.

  • Measure frequency: Use a frequency meter or multimeter with Hz function to measure output frequency. Compare to the rated 50/60 Hz.
  • Adjust governor: For mechanical governors, adjust the governor screw slightly to bring frequency into range. For electronic governors, follow Hyundai Power calibration procedures.
  • Inspect speed sensor: Check the engine speed sensor and wiring for damage or loose mounting. Replace if readings are erratic.
  • Controller configuration: Ensure the controller is set to the correct nominal frequency for your region. Incorrect settings can cause nuisance E15 alarms.
  • Load evaluation: Remove large intermittent loads (elevators, large compressors) and see if frequency stabilizes. If so, consider load management or a larger generator.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Electronic Governor Module
Check Price on Amazon