E02
JCB
Low Fuel Pressure / Fuel Supply Fault
Controller shows E02 and the engine cranks but does not fire, then locks out on shutdown.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked primary fuel filter, Air in fuel lines, Failed electric lift pump, Fuel solenoid not opening
How to Fix / Troubleshooting
Safety: Isolate battery negative and ensure no open flames. Diesel fuel is flammable; use absorbent pads for spills.
- Check fuel level: Confirm the day tank and bulk tank have adequate fuel and that any manual isolation valves on the JCB fuel line are open.
- Inspect filters: Locate the primary and secondary fuel filters on the JCB engine (often spin‑on canisters). Check for contamination or water. Replace if clogged and prime according to the engine manual.
- Bleed air: Use the manual priming pump or electric lift pump bleed screw to remove air from the system until fuel flows bubble‑free.
- Test lift pump: With battery connected, turn key to run and listen/feel for the electric lift pump operation. If silent, check fuse and relay; replace the lift pump if not running with power present.
- Check fuel shutoff solenoid: Verify the fuel solenoid on the injection pump is energizing during crank. If not, test voltage at the solenoid and replace if it does not actuate.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Fuel Lift Pump
Check Price on Amazon
We may earn a commission from links on this page.