Possible Causes

Fuel solenoid stuck open, Stop relay failure, Broken stop cable (mechanical stop), Controller output fault

How to Fix / Troubleshooting

Safety: Be prepared to use the emergency stop if normal stop fails. Keep clear of moving parts.

  • Use manual stop: Operate the emergency stop button or manual stop lever on the JCB engine to shut down.
  • Check fuel solenoid: Verify that the fuel shutoff solenoid de‑energizes when stop is commanded. If it remains energized, test the stop relay and controller output.
  • Mechanical linkage: For mechanically stopped engines, inspect the stop cable and lever for free movement and correct adjustment.
  • Replace faulty components: Replace a sticking fuel solenoid or defective stop relay as needed.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Fuel Shutoff Solenoid