Kipor No DC Power to Controller

Control panel on Kipor generator is dead; no lights or display, generator will not respond

Advertisements

Possible Causes

Disconnected or dead battery, Blown main DC fuse, Loose ground strap, Shorted controller

How to Fix / Troubleshooting

Safety first: Ensure battery cables cannot short to chassis while working.

  • Step 1 – Check battery: Verify battery voltage and polarity. Reconnect any loose cables and clean terminals.
  • Step 2 – Inspect DC fuse: Locate the main DC fuse near the battery or controller. Replace if blown with the same rating.
  • Step 3 – Verify ground: Ensure the engine and controller ground straps are secure and free of corrosion.
  • Step 4 – Controller test: If power and ground are present at the controller connector but it remains dead, replace the Kipor control module.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Main DC Fuse
Check Price on Amazon

We may earn a commission from links on this page.