Kipor
No DC Power to Controller
Control panel on Kipor generator is dead; no lights or display, generator will not respond
Advertisements
Possible Causes
Disconnected or dead battery, Blown main DC fuse, Loose ground strap, Shorted controller
How to Fix / Troubleshooting
Safety first: Ensure battery cables cannot short to chassis while working.
- Step 1 – Check battery: Verify battery voltage and polarity. Reconnect any loose cables and clean terminals.
- Step 2 – Inspect DC fuse: Locate the main DC fuse near the battery or controller. Replace if blown with the same rating.
- Step 3 – Verify ground: Ensure the engine and controller ground straps are secure and free of corrosion.
- Step 4 – Controller test: If power and ground are present at the controller connector but it remains dead, replace the Kipor control module.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements