Possible Causes

Faulty battery charger, Parasitic draw from accessories, Old battery with high self‑discharge, Loose or corroded terminals

How to Fix / Troubleshooting

Safety first: Disconnect battery negative before inserting an ammeter in series.

  • Step 1 – Test charger output: With AC supply present, measure DC voltage at the battery. It should be around 13.5–13.8 V. Replace charger if output is low or absent.
  • Step 2 – Check for parasitic draw: With generator off, measure current draw from the battery. Identify and disconnect accessories causing excessive draw.
  • Step 3 – Evaluate battery health: Load‑test the battery. Replace if it fails to maintain voltage under load.
  • Step 4 – Clean terminals: Remove corrosion and apply dielectric grease to battery posts.