AL10
Kohler-SDMO
High Oil Temperature Shutdown
Controller displays AL10 / Oil Temperature High and engine shuts down under load
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Insufficient engine oil, Blocked oil cooler, Failed oil cooler thermostat (if equipped), Excessive engine load or poor ventilation in generator room
How to Fix / Troubleshooting
Safety first: Stop the generator, open the output breaker, disconnect battery negative, and allow the engine to cool.
- Check oil level: Verify oil level with the dipstick and top up with the recommended oil if low.
- Inspect ventilation: Ensure air intake and discharge openings in the Kohler-SDMO canopy or room are not blocked. Remove obstructions and clean dust buildup.
- Check oil cooler: Inspect the external oil cooler (if fitted) for blocked fins or oil leaks. Clean fins with low-pressure air and repair leaks.
- Sensor and wiring: Locate the oil temperature sensor on the engine block or oil gallery. Check wiring and connector for damage. Replace the sensor if readings are clearly abnormal.
- Reset and test: Clear AL10 and run the generator under moderate load while monitoring oil and coolant temperatures.
Persistent high oil temperature may indicate internal engine issues; consult a qualified technician.