Controller displays AL24 / Frequency High and disconnects load
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Open the generator breaker and set controller to OFF before adjusting speed or governor components.
- Verify configuration: Check that the controller is configured for the correct nominal frequency (50 or 60 Hz) for your region and generator.
- Inspect speed sensor: Check the magnetic pickup sensor for correct gap and secure mounting.
- Adjust governor: On mechanical governors, adjust the speed setting screw slightly to reduce speed while monitoring frequency with a meter.
- Electronic governor: For electronic governors, follow Kohler-SDMO procedures to recalibrate speed setpoint.
- Reset alarm: Clear AL24 and test under load, ensuring frequency remains within tolerance.
Incorrect frequency can damage connected equipment; if you are not experienced with governor adjustment, contact a technician.
Repair Difficulty
Required Part
We may earn a commission from links on this page.