E04
Kubota
Underspeed / Underfrequency Shutdown
Kubota standby generator shuts down during run and displays E04, will restart but trips again after a short period.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Excessive electrical load, Fuel restriction to engine, Weak governor actuator, Clogged air filter reducing combustion air
How to Fix / Troubleshooting
Safety first: Open the main breaker to isolate the generator from the building load before troubleshooting. Disable auto-start and disconnect battery negative if working near moving parts.
- Reduce load: With the generator running, verify that the total connected load does not exceed the generator's rated kW. Turn off large loads (HVAC, water heaters) and see if the fault clears.
- Check fuel supply: Inspect the diesel fuel level in the tank. Open the fuel shutoff valve fully. Replace the Kubota primary and secondary fuel filters if they are old or contaminated. Bleed air from the fuel system using the manual priming pump and bleed screws on the injection pump.
- Inspect air filter: Remove the air filter element and check for heavy dirt or oil saturation. Replace with a genuine Kubota air filter if restricted.
- Governor linkage: Observe the governor actuator and throttle linkage while the engine runs. Ensure there is no binding and that the actuator responds quickly to load changes. Lubricate linkage lightly.
- Frequency check: Use a multimeter with frequency function at the generator output. If frequency remains low even at no load, the governor may need calibration by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Fuel Filter Set
Check Price on Amazon
We may earn a commission from links on this page.