Kubota
Controller Display Failure / Power Issue
Generator controller display is blank or unreadable, but the engine may still run or attempt to start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown controller fuse, Failed display backlight, Loose controller power connector, Internal controller fault
How to Fix / Troubleshooting
Safety first: Turn OFF the generator and disconnect battery negative before removing the controller or display panel.
- Check fuses: Locate and test the low-voltage fuses supplying the Kubota controller. Replace any blown fuses with the correct rating.
- Verify supply voltage: Measure DC voltage at the controller power terminals. It should match battery voltage. If absent, trace wiring back to the battery and charger.
- Inspect connectors: Reseat the multi-pin connector(s) on the back of the controller/display. Look for bent pins or corrosion.
- Backlight test: In a dark environment, check if any faint characters are visible. If so, the backlight may have failed and the display module may need replacement.
- Controller replacement: If power is present and wiring is good but the display remains dead, replace the controller with a Kubota-approved unit and transfer configuration settings.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Generator Control Module
Check Price on Amazon
We may earn a commission from links on this page.