Lifan
Load Step Response / Insufficient Capacity
Generator starts and then stalls when large loads (like air conditioners) start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Generator undersized for connected loads, Weak engine due to poor maintenance, Faulty governor response, Sticking choke (gas models)
How to Fix / Troubleshooting
Safety first: Isolate the generator from the building before reconfiguring loads. Turn OFF the generator when working inside the enclosure.
- Review load sizing: Compare the Lifan generator kW rating to the total starting and running kW of connected loads. Consider adding soft-start kits to large motors or reconfiguring load priorities.
- Engine tune-up: Replace air filter, fuel filter, and spark plug (gas) or service injectors (diesel) to restore full power.
- Check choke operation: Ensure the automatic choke on gasoline models opens fully after warm-up. A stuck choke can cause stalling under load. Replace the choke thermostat or linkage if faulty.
- Governor adjustment: Verify governor linkage is free and adjusted per Lifan specs to respond quickly to load changes.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Governor Actuator
Check Price on Amazon
We may earn a commission from links on this page.