Code 29
Onan Low AC Output Voltage

Generator shuts down; Code 29 displayed indicating low voltage output

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed voltage regulator, Weak residual magnetism in alternator, Shorted stator winding, Incorrect engine speed (underspeed)

How to Fix / Troubleshooting

Safety first: Open the main breaker and disable auto-start. Use a true RMS voltmeter rated for the generator voltage.

  • Verify engine speed: Use a tachometer to confirm engine RPM is at the specified value (e.g., 1800 or 3600 RPM depending on model). Correct any governor issues causing underspeed.
  • Measure output voltage: With no load, measure line-to-line and line-to-neutral voltages at the generator terminals. If significantly low, suspect regulator or alternator issues.
  • Inspect regulator connections: Check the voltage regulator harness for loose or burned connectors. Reseat and clean as needed.
  • Test regulator: Follow Onan service procedures to test the regulator. If it fails tests, replace with the correct Onan part.
  • Alternator check: If a new regulator does not restore voltage, the stator or rotor may be damaged and require professional replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Voltage Regulator
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements