Code 45
Onan
Low Fuel Level Shutdown
Generator shuts down; Code 45 displayed indicating fuel level low (if equipped with level sensor)
Advertisements
Possible Causes
Fuel tank level below shutdown threshold, Faulty fuel level sensor, Wiring issue between sensor and controller, Incorrect sensor calibration
How to Fix / Troubleshooting
Safety first: Disable auto-start. Handle fuel in a well-ventilated area away from ignition sources.
- Verify fuel level: Physically check the fuel tank level. If low, refill with the correct fuel type (diesel, gasoline, LP) and bleed the system if required.
- Inspect fuel level sensor: Check the sensor mounting on the tank and its wiring harness. Look for corrosion or damage.
- Sensor test: If the tank is adequately filled but Code 45 persists, test the sensor resistance or output per Onan specifications. Replace if out of range.
- Calibration: Some systems require calibration of the level sensor in the controller. Follow the service manual procedure if applicable.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Fuel Level Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements