Onan Fuel Shutoff Solenoid Circuit Failure

Generator shuts down; Code 47 displayed indicating fuel solenoid circuit fault

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted fuel solenoid coil, Broken solenoid wiring, Blown DC fuse feeding solenoid, Failed controller solenoid driver

How to Fix / Troubleshooting

Safety first: Disable auto-start and disconnect battery negative before working on the solenoid wiring.

  • Listen for solenoid operation: When turning the key or start command on, listen for a click at the fuel solenoid. No click suggests a problem.
  • Check fuses: Inspect DC control fuses in the generator control box. Replace any blown fuses with the correct rating and investigate cause.
  • Test solenoid coil: Disconnect the solenoid and measure coil resistance. An open or very low reading indicates a bad solenoid—replace it.
  • Inspect wiring: Check harness from controller to solenoid for damage. Repair as needed.
  • Controller driver: If the solenoid and wiring are good but no voltage is supplied, the controller output may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Fuel Shutoff Solenoid