Pramac
Inadequate Ventilation / Cooling Airflow Restriction
Generator enclosure becomes very hot to the touch during operation
Advertisements
Possible Causes
Blocked air intake or exhaust louvers, Failed enclosure ventilation fan (if equipped), Installation too close to walls or obstructions, Excessive ambient temperature
How to Fix / Troubleshooting
Safety first: Surfaces may be hot. Allow cooling before touching panels.
- Clear obstructions: Maintain the minimum clearance around the Pramac generator specified in the installation manual. Remove vegetation, snow, or stored items blocking airflow.
- Clean louvers and screens: Brush or vacuum dust and debris from intake and exhaust grilles.
- Check ventilation fan: On models with electric fans, verify operation during run. Replace failed fans and check their fuses.
- Monitor temperature: After corrections, run the unit under load and periodically check enclosure temperature. Persistent overheating may require airflow redesign.