Pramac Loss of Output / Open Output Breaker

Generator runs but produces no AC power, no error code on controller

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Output breaker tripped, Loose output cable connections, Failed alternator stator winding, Faulty AVR with no excitation

How to Fix / Troubleshooting

Safety first: Treat all terminals as live until proven otherwise. Isolate generator from load and utility.

  • Check output breaker: Verify that the generator's main circuit breaker is in the ON position. Reset if tripped.
  • Measure voltage: With a multimeter, check voltage at the alternator terminals and at the load side of the breaker. If voltage is present at alternator but not at load, suspect the breaker or wiring.
  • Inspect connections: Tighten all lugs in the alternator terminal box and at the breaker.
  • AVR/alternator: If no voltage is present at the alternator, the AVR or stator may have failed. This typically requires professional testing and replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Generator Output Circuit Breaker
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements