Scheppach
Display / HMI Failure
Control panel display is blank or unreadable, generator otherwise runs
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown display backlight fuse, Loose ribbon cable to LCD, Failed HMI module, Moisture ingress into control panel
How to Fix / Troubleshooting
Safety first: Turn OFF the generator and disconnect battery negative before opening the control panel.
- Check contrast/brightness: Some Scheppach panels have a contrast or brightness adjustment. Verify it is not turned down.
- Inspect fuses: Look for a small fuse dedicated to the display or HMI. Replace if blown.
- Reseat ribbon cable: Carefully open the controller housing and reseat the ribbon cable connecting the main board to the display.
- Dry moisture: If condensation is present, dry the panel gently and improve enclosure sealing.
- Replace HMI: If the display remains blank, replace the HMI/display module with the correct Scheppach part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel Display Module
Check Price on Amazon