E09
Scheppach Overvoltage / AVR Regulation Fault

Generator runs but voltage is too high, E09 overvoltage alarm on display

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective AVR, Incorrect AVR sensing wiring, Poor neutral connection, Incorrect voltage selection setting on controller

How to Fix / Troubleshooting

Safety first: Turn OFF the generator and disconnect it from all loads. High voltage can damage appliances.

  • Verify voltage selector: On Scheppach models with a voltage selector switch or controller setting, confirm it is set to the correct output (e.g., 230 V single‑phase or 400 V three‑phase). Do not change settings under load.
  • Inspect neutral and sensing leads: Remove the alternator terminal cover and locate the AVR sensing wires (often connected between a phase and neutral). Ensure all connections are tight and not corroded. Repair any loose or burnt terminals.
  • Check neutral bond: Confirm the generator neutral connection is secure at the alternator and terminal block. A floating or intermittent neutral can cause unstable voltage.
  • Replace AVR: If wiring is correct and E09 persists, replace the AVR with the exact Scheppach‑specified part. Mount it securely and reconnect all wires as per the diagram.
  • Test under light load: Start the generator and measure voltage with a true‑RMS meter. Confirm it remains within ±5% of nominal under light and moderate load.