AL05
SDMO Engine Underspeed / Underfrequency

Generator shuts down with AL05 indicating underspeed; engine runs rough and cannot reach rated frequency.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Fuel restriction in SDMO fuel filter or lines, Faulty or misadjusted governor, Heavy load applied too quickly, Clogged air filter reducing combustion air

How to Fix / Troubleshooting

Safety first: Place the generator in OFF, isolate load, and allow the engine to cool before servicing fuel or air systems.

  • Inspect and replace fuel filters: Check the SDMO primary and secondary fuel filters for contamination. Replace if dirty or waterlogged. Bleed the fuel system after replacement.
  • Check for fuel line restrictions: Inspect flexible hoses and rigid lines for kinks, collapsed sections, or partially closed valves. Ensure the SDMO fuel transfer pump (if fitted) is operating correctly.
  • Clean or replace air filter: Remove the air filter element and inspect. If heavily soiled, replace with the correct SDMO-specified element. Do not run without a filter except briefly for testing.
  • Verify governor linkage: On mechanical governors, ensure linkages move freely and return springs are intact. On electronic governors, check the actuator for full travel and recalibrate if required per SDMO/engine manual.
  • Load test: After clearing AL05, start the generator and gradually apply load while monitoring frequency. Avoid sudden full-load application on a cold engine.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Fuel Filter Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements