AL07
SDMO
Low DC Battery Voltage
Generator stops and controller displays AL07 indicating battery low voltage alarm.
Advertisements
Possible Causes
Aged or failing SDMO starter battery, Faulty battery charger module, Loose or corroded battery terminals, Parasitic drain from control circuits
How to Fix / Troubleshooting
Safety first: Set controller to OFF and isolate AC output. Wear eye protection when working around batteries.
- Measure battery voltage: With the charger connected, measure DC voltage at the battery terminals. For 12 V systems expect ~13.5–13.8 V; for 24 V systems ~27–27.6 V. If significantly lower, suspect the charger or battery.
- Inspect terminals and cables: Clean corrosion from battery posts and cable lugs using a wire brush. Tighten all connections to the SDMO starter and ground points.
- Test battery capacity: Perform a load test with an appropriate tester. Replace the SDMO starter battery if it fails to maintain voltage under load.
- Check battery charger: Verify AC supply to the SDMO battery charger module. If AC is present but output is low or zero, replace the charger. Inspect DC output fuse if fitted.
- Reset alarm: After correcting the issue, clear AL07 and confirm that the controller shows normal battery voltage.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Battery Charger Module
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements