SDMO
Nuisance Auto-Start / Cycling
SDMO generator frequently starts and stops for short periods even when load is low or absent.
Advertisements
Possible Causes
Incorrect exercise timer settings, Unstable mains voltage detection thresholds, Faulty mains sensing circuit, Misconfigured remote start input
How to Fix / Troubleshooting
Safety first: Ensure that automatic starts are disabled while adjusting controller settings.
- Review exercise schedule: Check the SDMO controller's exercise or test timer. Adjust frequency and duration to appropriate values.
- Check remote start input: Inspect wiring to any remote start contacts. A chattering or intermittent contact can cause repeated starts.
- Verify mains sensing thresholds: Ensure that undervoltage/overvoltage limits are not set too tight, causing frequent perceived mains failures.
- Monitor mains stability: Use a power quality meter to confirm that mains supply is stable. If not, consult the utility provider.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Remote Start Input Module
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements