F27
Siemens Starter Circuit Failure

Controller displays F27 Starter Fault; generator does not crank when start is commanded.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown starter fuse, Faulty starter relay, Defective starter motor, Loose battery or starter cable connections

How to Fix / Troubleshooting

Safety first: Disable auto-start and remove the key (if equipped). Keep hands and tools clear of the engine flywheel and belts.

  • Listen for relay click: When a start is commanded, listen for a click from the starter relay. No click suggests a control or relay issue; a click with no crank suggests a starter or power issue.
  • Check fuses: Inspect the starter circuit fuse or breaker in the DC panel. Replace if blown with the correct rating.
  • Inspect cables: Tighten battery positive and negative cables and the heavy cable to the starter motor. Look for burned or loose lugs.
  • Test starter relay: With a multimeter, verify that the relay coil receives voltage during a start command and that the relay output closes. Replace the relay if it fails.
  • Starter motor test: If power is present at the starter but it does not turn, the starter motor is likely defective and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Starter Motor
Check Price on Amazon