Siemens No-Start Condition Without Logged Fault

Generator cranks but will not start; no error code displayed on Siemens controller.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Empty fuel supply, Ignition system failure (gas), Air in diesel fuel system, Controller in OFF or MANUAL mode without start command

How to Fix / Troubleshooting

Safety first: Disable auto-start and keep clear of moving parts during crank attempts.

  • Verify controller mode: Ensure the Siemens controller is set to AUTO or MANUAL as required and that a start command is actually being issued (utility fail or manual start button).
  • Check fuel: Confirm gas valves are open and gas supply is available, or that diesel tank has sufficient fuel. For diesel, prime the fuel system using the manual pump and bleed air at injector lines if necessary.
  • Inspect ignition (gas): For gas engines, remove a spark plug lead and use a spark tester to verify spark during crank. Replace ignition coil pack or spark plugs if no spark is present.
  • Review recent changes: If wiring or settings were recently changed, restore them to the last known good configuration.
  • Call technician if unresolved: Persistent no-start without codes may indicate deeper engine or controller issues requiring professional diagnostics.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ignition Coil Pack
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements