E05
Wacker Neuson
Low Fuel Level / Fuel Supply Fault
Generator starts then stops within a few seconds, controller logs E05
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low diesel or gasoline level in tank, Clogged fuel filter, Air in fuel lines, Faulty fuel lift pump
How to Fix / Troubleshooting
Safety first: Turn OFF the generator and disconnect battery negative. Work in a well-ventilated area away from open flames.
- Verify fuel level: Check the tank gauge and visually confirm fuel level if possible. Refill with the correct fuel type specified for your Wacker Neuson standby generator (diesel or gasoline).
- Inspect fuel lines: Look for wet spots, cracks, or loose hose clamps between the tank, fuel filter, and injection pump/carburetor. Tighten or replace as needed.
- Replace fuel filter: Locate the primary fuel filter/water separator. Close any fuel shutoff valve, remove the filter, and install a new OEM filter. Prime according to the manual (use hand primer or bleed screws).
- Bleed air from system (diesel): Loosen the bleed screw on the fuel filter or injection pump and operate the hand primer until fuel flows without bubbles. Tighten the screw.
- Check fuel lift pump: With ignition ON, verify that the electric lift pump (if equipped) runs and delivers fuel. For mechanical pumps, crank the engine and check for fuel flow at the filter outlet.
- Reset and test: Clear E05 on the controller and start the generator. Monitor for stable running under light load.