E11
Wacker Neuson
Overcrank / Failed to Start
Controller shows E11 and logs multiple failed start attempts
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
No fuel delivery, Faulty glow plugs (diesel), Ignition failure (gasoline), Incorrect start sequence or controller configuration
How to Fix / Troubleshooting
Safety first: Allow the starter to cool between attempts to avoid damage. Disable AUTO mode before working on the unit.
- Check fuel supply: Confirm fuel level and that any manual shutoff valves are open. Replace the fuel filter if restricted.
- Inspect glow plug circuit (diesel): Verify the glow plug indicator (if present) illuminates during preheat. Measure voltage at glow plugs during preheat; if absent, check the glow plug relay and fuse.
- Test glow plugs: Remove and bench-test for correct resistance and heating. Replace any open or weak plugs.
- Ignition check (gasoline): Remove a spark plug, reconnect the lead, ground the plug body, and crank. Look for strong blue spark. Replace plugs or ignition coil if spark is weak or absent.
- Air intake: Ensure the air filter is not completely blocked. Replace if heavily contaminated.
- Controller parameters: Confirm that fuel type and start delay settings in the Wacker Neuson controller match the engine. Incorrect settings can shorten preheat or crank time.
- Clear E11: After correcting issues, reset the controller and attempt a manual start.
Advertisements
Repair Difficulty
Medium