E16
Wacker Neuson High Oil Temperature Shutdown

Generator shuts down with E16 when oil temperature rises, even though coolant temperature is normal

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low engine oil level, Blocked oil cooler, Failed oil temperature sensor, Restricted airflow around oil cooler

How to Fix / Troubleshooting

Safety first: Allow the engine to cool completely. Disconnect battery negative before working near rotating parts or wiring.

  • Check oil level: Verify oil level on the dipstick and top up with the specified oil if low.
  • Inspect oil cooler: Locate the oil cooler (air-to-oil or coolant-to-oil). Clean external fins with compressed air and ensure no debris blocks airflow.
  • Check oil temperature sensor: Inspect the sensor and wiring. Test resistance versus temperature according to the service manual. Replace if out of specification.
  • Verify ventilation: Ensure the generator enclosure fans and louvers are functioning and not obstructed.
  • Reset and test: Clear E16 and run the generator while monitoring oil temperature via the controller.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Oil Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements