Wacker Neuson
Crank Disconnect Failure (Starter Not Disengaging)
Controller displays E17 and logs during cranking phase
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Sticking starter solenoid, Welded starter relay contacts, Faulty crank disconnect signal from controller, Shorted wiring to starter solenoid
How to Fix / Troubleshooting
Safety first: Immediately stop the generator if the starter remains engaged. Disconnect battery negative to prevent further damage.
- Inspect starter solenoid: Check for signs of overheating or melting. Replace the solenoid if contacts are welded.
- Test starter relay: Locate the crank relay in the control panel. Verify that it de-energizes when the engine reaches running speed. Replace if it remains stuck closed.
- Check wiring: Inspect the wire from the relay to the starter solenoid for shorts to positive. Repair any damaged insulation.
- Controller settings: Confirm that crank disconnect parameters (speed or voltage threshold) are correctly set in the Wacker Neuson controller.
- Reset E17: After repairs, reconnect the battery and test start while listening for proper starter disengagement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Starter Solenoid
Check Price on Amazon
We may earn a commission from links on this page.