E15
WEN Excessive Crank Attempts / Start Retry Lockout

Controller shows E15 and the generator refuses to start after several failed attempts.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Persistent no‑start condition (fuel or ignition), Controller lockout timer active, Faulty crank relay, Weak battery causing incomplete cranks

How to Fix / Troubleshooting

Safety first: Avoid repeated cranking to prevent starter and battery damage. Turn the generator OFF and disconnect the battery negative cable before inspecting components.

  • Clear lockout: Many WEN controllers require a manual reset after multiple failed start attempts. Press and hold the STOP/RESET button or follow the menu procedure to clear E15.
  • Address root cause: Investigate why the engine is not starting: verify fuel supply, check spark plugs and ignition coils, and ensure the air filter is not clogged. Correct any issues found.
  • Inspect crank relay: Locate the starter (crank) relay in the control compartment. Check for loose connections and test the relay coil and contacts with a multimeter. Replace the starter relay if it fails tests.
  • Check battery and cables: Ensure the starting battery is fully charged and that all cable connections are clean and tight. High resistance in the cables can cause slow cranking and failed starts.
  • Test start again: After correcting issues and clearing E15, attempt a manual start while monitoring for proper cranking speed and ignition.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Starter Relay
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements