E19
Westinghouse Remote Monitoring / Network Communication Fault

Controller displays E19 and logs communication errors with remote monitoring

Advertisements

Possible Causes

Disconnected Ethernet or cellular modem cable, failed remote monitoring module, incorrect network configuration, power loss to communication module

How to Fix / Troubleshooting

Safety first: Ensure the generator is in a safe state (OFF and breaker open) before working inside the control compartment.

  • Check communication module power: Verify that the remote monitoring module (Ethernet or cellular) has DC power from the control board. Check its fuse if present.
  • Inspect network cabling: Ensure Ethernet cables are fully seated and not damaged. Replace any suspect cables.
  • Verify configuration: Access the controller or web interface (if available) and confirm that network settings (IP, APN, etc.) are correct per your monitoring provider.
  • Reboot module: Power-cycle the communication module by disconnecting and reconnecting its power connector.

If E19 persists but generator operation is otherwise normal, remote monitoring hardware may need replacement.

Advertisements

Repair Difficulty

Easy 2/5