E17
Winco Low Fuel Pressure / Fuel Supply Fault

Controller shows E17 / FUEL PRESSURE LOW or FUEL SUPPLY FAULT and the engine stalls or will not start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Closed gas shutoff valve, Low LP tank level or low NG line pressure, Blocked fuel filter, Faulty gas regulator at generator

How to Fix / Troubleshooting

Safety first: Turn off AUTO and avoid open flames. Work in a well-ventilated area when dealing with gas.

  • Verify gas valves: Confirm the main LP/NG shutoff valve at the tank and the valve at the generator are fully open.
  • Check fuel level: For LP, verify tank gauge shows adequate level (typically above 30%). For NG, consult your gas supplier if pressure is suspect.
  • Inspect regulator and filter: Examine the gas regulator and any inline fuel filter at the generator for icing, contamination, or damage. Replace a clogged filter.
  • Leak check: Use a gas leak detector solution on fittings. Repair any leaks before restarting.

If E17 persists with confirmed gas supply, the regulator or internal fuel system should be tested by a licensed gas technician.