E71
Amica NTC Sensor Circuit Fault

E71 displayed; temperature readings erratic; cycles end too early or too late

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted NTC sensor, Damaged sensor wiring, Poor connector contact at PCB, Incorrect replacement sensor fitted

How to Fix / Troubleshooting

Safety first: Unplug the appliance.

  • Locate NTC: Find the wash NTC at the heater bracket and the dryer NTC in the air duct (depending on which circuit shows E71).
  • Measure resistance: Compare readings to Amica specifications at room temperature. Replace any sensor with out-of-range values.
  • Check connectors: Clean and reseat connectors at both sensor and PCB ends.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

NTC Temperature Sensor