Possible Causes

Faulty pushbuttons or encoder, damaged UI PCB tracks, loose ribbon cable to main board, liquid ingress into control panel

How to Fix / Troubleshooting

Safety: Unplug before removing the console.

Steps:

  • Inspect for spills: Look for signs of detergent or water ingress around the control panel; dry thoroughly.
  • Ribbon cable: Reseat the ribbon cable between UI and main board.
  • Button test: With the panel removed, press buttons and feel for proper tactile feedback. Replace the UI board if buttons are unresponsive or PCB is damaged.

Tip: Avoid spraying cleaners directly onto the control panel; apply to a cloth instead.