F05
Ariston Drain Pump or Pressure Switch Drain Fault

Washer-dryer will not drain; water remains in drum and F05 is displayed.

Advertisements

Possible Causes

Blocked drain pump filter, clogged drain hose, failed drain pump motor, blocked pressure chamber causing incorrect empty signal

How to Fix / Troubleshooting

Safety: Unplug the machine. Prepare towels and a shallow tray to catch water.

Clear blockages:

  • Clean pump filter: Open the lower front access flap. Slowly unscrew the pump filter cap and allow water to drain into a tray. Remove debris (coins, lint, buttons) from the filter and pump impeller area. Ensure the impeller spins freely.
  • Check drain hose: Inspect the external drain hose for kinks or clogs. Detach from the standpipe or sink trap and flush with water.
  • Inspect pump wiring: With the lower panel removed, check the pump electrical connector for corrosion or loose fit. Reseat it.
  • Test pump: With the machine unplugged, measure pump coil resistance (typically 150–300 Ω; check Ariston specs). If open or shorted, replace the pump.
  • Pressure system: If the pump runs but F05 persists, clean the pressure hose and chamber as described for F04 to ensure the control board correctly detects an empty tub.

Note: After cleaning, run a rinse and spin to confirm proper draining.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Drain Pump Assembly
Check Price on Amazon