H20
Ariston
Water Inlet / Fill Timeout Fault
Machine does not fill with water or fills very slowly; H20 or H2O error displayed.
Advertisements
Possible Causes
Closed or partially closed water tap, clogged inlet filter screens, faulty water inlet valve, low household water pressure
How to Fix / Troubleshooting
Safety: Turn off water supply and unplug the appliance.
Steps:
- Check taps: Ensure both hot and cold taps (if applicable) are fully open and hoses are not kinked.
- Clean inlet filters: Turn off taps, disconnect hoses from the rear of the machine, and remove the small mesh filters inside the valve inlets. Rinse under running water and reinstall.
- Test water flow: Briefly open the taps with hoses directed into a bucket to confirm strong flow from the household supply.
- Check inlet valve: If flow to the valve is good but the machine still does not fill, the solenoid valve may be faulty. Access the valve from the top, test coil resistance with a multimeter, and replace if open or shorted.
Tip: After reassembly, run a quick wash to confirm proper filling.
Advertisements
Repair Difficulty
Easy