E26
Balay
Analog Pressure Sensor Calibration Error
Washer-dryer shows E26; water level control appears unstable
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect sensor type fitted, Sensor out of calibration, Electrical noise on sensor line, Faulty main control ADC circuit
How to Fix / Troubleshooting
Safety first: Unplug the appliance.
Step-by-step checks:
- Verify correct part: Check that the installed analog pressure sensor matches the Balay part number for this model. An incorrect sensor can cause E26.
- Inspect wiring and routing: Ensure the sensor harness is not routed alongside high-voltage lines that could induce noise. Re-route if necessary.
- Replace sensor: If the correct sensor is installed but E26 persists, replace it with a new OEM sensor.
- Control board: If a new sensor does not resolve the issue, the main control's analog input may be defective and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Analog Pressure Sensor