E16
Blomberg Inlet Valve Control Circuit Failure

Washer-dryer shows E16; water inlet valve triac or control fault

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted water inlet valve coil, Shorted triac on main control board, Wiring short between valve and PCB, Moisture on control board

How to Fix / Troubleshooting

Safety first: Unplug the appliance and close water taps before inspection.

  • Inspect inlet valve: Remove the top cover and check the inlet valve assembly for signs of burning or melting. Replace the valve if damaged.
  • Test valve coils (qualified persons): Measure resistance of each coil. If any coil is significantly lower than specification or shorted, replace the valve.
  • Check wiring harness: Look for pinched or rubbed-through wires between the valve and control board. Repair or replace damaged sections.
  • Control board assessment: If the valve and wiring are good, the triac on the main PCB may be shorted, causing E16. Board-level repair or replacement is required and should be done by a qualified technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Water Inlet Valve
Check Price on Amazon

We may earn a commission from links on this page.