E8
Costway
Water Level Sensor / Pressure Switch Fault
Washer-dryer combo displays E8 and stops; water level appears incorrect (either overfilling or not filling enough).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked or kinked pressure hose, Faulty water level (pressure) sensor, Air leak in pressure hose connection, Wiring issue between sensor and control board
How to Fix / Troubleshooting
Safety first: Unplug the appliance and turn off water supply before removing covers.
- Locate pressure sensor: Typically mounted near the top side wall, connected to the tub by a small rubber hose.
- Inspect pressure hose: Check the entire length of the hose for kinks, cracks, or disconnections. Re-seat both ends firmly on the tub and sensor nipples.
- Clear blockages: Detach the hose from the sensor and gently blow through it toward the tub to clear soap residue or lint. Do not use sharp tools that could puncture the hose.
- Check for water in hose: If water is present in the hose, drain it and ensure the tub air chamber is not clogged with detergent buildup.
- Test sensor (advanced): With a multimeter, measure sensor output according to the service manual while applying gentle air pressure. Replace the sensor if readings are out of range or intermittent.
- Inspect wiring: Verify that the connector at the sensor and at the main PCB is secure and free of corrosion.
- If E8 persists: Replace the water level sensor. If the new sensor does not resolve the issue, suspect a control board fault.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Level Pressure Sensor
Check Price on Amazon