E19
Danby Dryer Temperature Sensor (NTC) Error

Washer-dryer combo shows E19 and may not heat properly during drying; temperature control seems erratic.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed dryer NTC sensor, Loose or corroded NTC wiring, Shorted sensor, Sensor dislodged from mounting point

How to Fix / Troubleshooting

Safety first: Unplug the appliance and allow it to cool before accessing dryer components.

  • Locate dryer NTC: Access the dryer air duct or heater housing and locate the temperature sensor (NTC) clipped into the duct.
  • Inspect wiring: Check the sensor connector and wiring harness for secure fit and no damage.
  • Test sensor: Use a multimeter to measure resistance at room temperature and compare to Danby specifications. A reading of near 0 Ω or infinite resistance indicates a bad sensor.
  • Ensure proper mounting: Make sure the sensor is properly seated in the duct so it can accurately sense air temperature.
  • Replace NTC: If faulty, install a new dryer temperature sensor and reassemble the ducting.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Dryer Temperature Sensor (NTC)
Check Price on Amazon