Electrical Short or Earth Leakage
Washer-dryer trips the household circuit breaker or RCD during operation
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Leaking tub heater to earth, Shorted dryer heater, Damaged mains filter, Water leak onto wiring
How to Fix / Troubleshooting
Safety first: Do not repeatedly reset a tripping breaker. Unplug the appliance and keep it disconnected until the fault is found.
- Step 1 – Visual inspection: Check for obvious water leaks around the machine and inside the base. Fix leaks before further testing.
- Step 2 – Isolate components: With the appliance unplugged, disconnect the tub heater and try running a cold wash. If the breaker no longer trips, the heater is likely faulty.
- Step 3 – Test heaters: Use a multimeter to check resistance from each heater terminal to earth (chassis). Any measurable leakage indicates a failed element that must be replaced.
- Step 4 – Check mains filter: Inspect the mains filter for burning or cracking. Replace if damaged.
- Step 5 – If unsure: Because of shock and fire risk, have a qualified electrician or appliance technician complete the diagnosis and repair.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Tub Heating Element
Check Price on Amazon