Fagor Moisture Sensing / Control Issue

Drying cycle stops prematurely and laundry is still wet.

Advertisements

Possible Causes

Dirty or coated moisture sensor bars, Faulty moisture sensor wiring, Incorrect program selection, Control board moisture sensing fault

How to Fix / Troubleshooting

Safety first: Unplug the appliance before cleaning sensor bars.

  • Step 1 – Clean sensor bars: Locate the metal moisture sensor strips inside the drum (usually near the door). Clean them with a soft cloth and mild detergent to remove any waxy softener film.
  • Step 2 – Check wiring: Access the rear of the sensor bars and ensure the wires are firmly connected and not broken.
  • Step 3 – Program selection: Use appropriate drying programs for the load type and size. Very small loads may not contact the sensors properly.
  • Step 4 – Control board: If issues persist, the Fagor control board’s moisture sensing circuit may require professional diagnosis.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Moisture Sensor Bars
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements