E10
Fagor Water Level Detection Fault

Washer-dryer stops mid-cycle with E10; often related to water level not detected correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty pressure switch, Blocked pressure chamber on tub, Split or blocked pressure hose, Control board analog sensing fault

How to Fix / Troubleshooting

Safety first: Unplug the appliance and close water taps.

  • Step 1 – Clean pressure chamber: Locate the pressure hose connection on the side or bottom of the tub. Remove the hose and inspect the tub spigot for soap scum or sludge. Clean thoroughly to ensure clear air passage.
  • Step 2 – Inspect and replace hose if needed: Check the entire length of the pressure hose for pinholes, splits, or kinks. Replace with the correct diameter hose if damaged.
  • Step 3 – Test pressure switch: Remove the Fagor pressure switch from its mount. With a multimeter, check continuity changes across its terminals while gently blowing into the hose connection. If switching is inconsistent or absent, replace the switch.
  • Step 4 – Wiring and PCB: Verify the connector at the pressure switch and at the main PCB is clean and firmly seated. If all components are good but E10 persists, the control board’s level sensing circuit may be defective and require professional service.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Water Level Pressure Switch
Check Price on Amazon