E18
Fagor Extended Drain Time / Partial Blockage

Washer-dryer shows E18 and may stop; often associated with drain time exceeding limit.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially blocked pump filter, Partially clogged drain hose, Weak drain pump, Siphoning due to incorrect drain hose installation

How to Fix / Troubleshooting

Safety first: Unplug the appliance and prepare for water spillage when opening the filter.

  • Step 1 – Clean pump filter thoroughly: Open the pump filter flap, drain residual water, and remove the filter. Clean all debris and check deeper inside for obstructions.
  • Step 2 – Check drain hose routing: Ensure the drain hose rises to the recommended height (usually 60–90 cm) before entering the standpipe. If too low, water can siphon out and confuse level sensing.
  • Step 3 – Flush drain hose: Disconnect the hose from the standpipe and flush it with water to remove internal buildup.
  • Step 4 – Evaluate pump performance: During a drain test (with panels removed and observing safely), check that water exits strongly. If the pump is noisy, weak, or intermittent, replace the Fagor drain pump.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Drain Pump
Check Price on Amazon