E19
Fagor
Dryer Condenser Water Circuit Fault
Washer-dryer shows E19; may be related to drying water circuit (for condenser type).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser water spray nozzle, Clogged internal recirculation hose, Faulty condenser water valve, Scale buildup in condenser channels
How to Fix / Troubleshooting
Safety first: Unplug the appliance and close water taps.
- Step 1 – Clean condenser and channels: Remove the condenser (if user-removable) and flush thoroughly. For fixed condensers, access internal channels and rinse or brush out scale and lint.
- Step 2 – Inspect water spray nozzle: Locate the small nozzle that sprays water over the condenser. Remove and clean it to clear limescale or debris.
- Step 3 – Check condenser water valve: Identify the dedicated Fagor condenser water inlet valve (if fitted). Test coil resistance and replace if open or not actuating.
- Step 4 – Hoses: Check internal hoses for kinks or blockages and replace if necessary.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Condenser Water Inlet Valve
Check Price on Amazon