E19
Fagor Dryer Condenser Water Circuit Fault

Washer-dryer shows E19; may be related to drying water circuit (for condenser type).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser water spray nozzle, Clogged internal recirculation hose, Faulty condenser water valve, Scale buildup in condenser channels

How to Fix / Troubleshooting

Safety first: Unplug the appliance and close water taps.

  • Step 1 – Clean condenser and channels: Remove the condenser (if user-removable) and flush thoroughly. For fixed condensers, access internal channels and rinse or brush out scale and lint.
  • Step 2 – Inspect water spray nozzle: Locate the small nozzle that sprays water over the condenser. Remove and clean it to clear limescale or debris.
  • Step 3 – Check condenser water valve: Identify the dedicated Fagor condenser water inlet valve (if fitted). Test coil resistance and replace if open or not actuating.
  • Step 4 – Hoses: Check internal hoses for kinks or blockages and replace if necessary.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Water Inlet Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements