E16
Fisher & Paykel
NTC Temperature Sensor Fault (Wash Circuit)
Washer-dryer combo displays E16; water temperature is incorrect or fluctuates wildly during wash.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed Fisher & Paykel NTC temperature sensor, Loose sensor connection, Wiring damage between NTC and control board, Control board analog input fault
How to Fix / Troubleshooting
Safety first: Disconnect power and allow the machine to cool before servicing.
- Access NTC sensor: The wash NTC is typically mounted in the heater bracket or inserted into the outer tub. Remove the rear or front lower panel to locate it.
- Check connector: Ensure the NTC wiring plug is fully seated and free of corrosion.
- Test NTC: With a multimeter, measure resistance at room temperature and compare with Fisher & Paykel service values (commonly around 20 kΩ at 25°C, but verify for your model). If readings are far off or open, replace the sensor.
- Replace NTC: Gently pull the sensor from its housing, install the new NTC with any supplied sealant or O-ring, and reconnect wiring.
- Control board: If a known-good NTC still results in E16, the main control board may have a faulty input circuit and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Fisher & Paykel Wash NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.