E72
GE Water Level Sensor Calibration / Range Error

Washer-dryer combo shows E72; unit may not detect water level correctly and can abort cycles.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect sensor calibration, Faulty GE water level sensor, Control board misreading sensor, Air leak at tub pressure dome

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing internal components.

  • Check pressure dome: Locate the pressure dome or port on the side of the outer tub where the pressure hose connects. Ensure it is not cracked or clogged with detergent residue. Clean gently if needed.
  • Verify hose fit: Make sure the pressure hose is snug on both the tub and sensor fittings. Replace the hose if it is loose or hardened.
  • Sensor replacement: If E72 appears repeatedly and hose/dome are good, replace the GE water level/pressure sensor.
  • Control reset: After replacement, perform any required calibration or reset procedure described on the unit's tech sheet (often involves entering service mode and running a calibration cycle).
Advertisements

Repair Difficulty

Hard 4/5

Required Part

GE Water Level / Pressure Sensor
Check Price on Amazon

We may earn a commission from links on this page.