E22
Hoover
Dryer Condenser / Pump Fault (where fitted)
Washer-dryer shows E22; often associated with drying cycle not starting or aborting
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser unit, Failed condenser pump, Blocked condenser drain path, Faulty condenser level sensor
How to Fix / Troubleshooting
Safety: Unplug the appliance. Water may be present in internal trays.
- Clean condenser: Remove the condenser (if user-removable) and rinse thoroughly to remove lint and scale. Allow to dry and reinstall.
- Check internal drain paths: Access the lower rear or side panel to inspect the condenser drain hose and tray. Clear any lint or sludge.
- Inspect condenser pump: Some Hoover combos use a small pump to move condensed water. Check for obstructions and test the pump for continuity.
- Level sensor: If a float or level sensor is present in the condenser tray, ensure it moves freely and is clean.
- Replace components: Replace the condenser pump or level sensor if they fail electrical tests or are physically damaged.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Condenser Pump
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements