Hotpoint-Ariston
Voltage Drop / Loose Electrical Connection
Display and lights flicker or reset when the washer-dryer starts spinning or heating.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak household circuit or undersized wiring, Loose power plug or socket, Loose internal mains connections, Failing mains filter or control board power supply
How to Fix / Troubleshooting
Safety: Unplug the appliance before opening any panels.
- Check outlet and plug:
- Ensure the plug fits tightly in the socket.
- Avoid using extension leads or multi-way adapters.
- Inspect internal mains connections:
- Remove the top or rear panel.
- Check the terminal block, mains filter, and control board input connectors for tightness and signs of overheating.
- House wiring: If other appliances also cause flicker, consult an electrician to check the circuit capacity.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Mains Interference Filter (EMI Filter)
Check Price on Amazon