E23
Liebherr Drain Pump Triac / Control Fault

Washer-dryer shows E23; drain pump may not run at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted drain pump, Burnt triac on main PCB, Wiring short to pump, Water ingress on control board

How to Fix / Troubleshooting

Safety first: Unplug the appliance. Water and electricity are a dangerous combination.

  • Check pump for short: Disconnect the pump and measure coil resistance. A very low resistance or visible burning indicates a shorted pump; replace it.
  • Inspect wiring: Check the harness from the PCB to the pump for insulation damage or signs of arcing. Repair or replace as needed.
  • Control board inspection: Examine the main PCB for burnt components near the pump triac. If damaged, the board must be replaced.
  • Prevent recurrence: Ensure no leaks are dripping onto the control board or pump area.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon