E17
NewAir Overfill / Water Level Control Failure

Washer-dryer combo shows E17; water level rises too high or overflows into the drum.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck water inlet valve, Blocked pressure hose, Faulty water level sensor, Control board not shutting off valve

How to Fix / Troubleshooting

Safety first: Turn off water supply and unplug the unit immediately if overfilling occurs.

  • Shut off water: Close both hot and cold supply valves to stop filling.
  • Inspect inlet valve: If water continues to flow into the drum with power off, the inlet valve is mechanically stuck open and must be replaced.
  • Check pressure hose and sensor: Remove the top panel and inspect the pressure hose and sensor as described for E7. Clear any blockages and ensure tight connections.
  • Test fill: Restore water and power, then run a small cycle while monitoring the fill level. If overfilling recurs, replace the water level sensor and/or inlet valve assembly.
  • Control board check: If valves and sensor are new and correctly installed, the main control board may be failing to shut off the valve and should be evaluated by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Water Level Pressure Sensor