E15
Proline Power Supply / Overcurrent Fault

Washer-dryer trips the household breaker or shows E15 related to power issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted heating element, Shorted motor windings, Damaged mains filter (EMI filter), Internal wiring short to chassis

How to Fix / Troubleshooting

Safety first: If the breaker trips, do not repeatedly reset it. Unplug the appliance and do not use it until the fault is identified.

Step-by-step checks:

  • Visual inspection: Remove the rear panel and top cover. Look for burnt wires, melted connectors, or scorch marks on components.
  • Check mains filter: Inspect the mains interference filter where the power cord enters the machine. If swollen, cracked, or burnt, replace it.
  • Test heater and motor: With a multimeter, test the wash heater, dryer heater, and motor windings for resistance to earth (chassis). Any continuity to earth indicates a shorted component that must be replaced.
  • Wiring harness: Follow wiring looms for signs of chafing against metal edges. Repair or replace damaged sections.

When to call a technician: Because this involves mains safety and potential fire risk, professional diagnosis is strongly recommended.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Mains Interference Filter